HC-SR04 Distance Measuring Module: Difference between revisions
(Created page with "== Features == {| class="wikitable" style="float:right; margin-left: 10px;" | {{FULLPAGENAME}} | {{#qrlite:{{fullurl:{{FULLPAGENAME}}}}|format=svg|size=2|ecc=1|margin=0}} |-...") |
No edit summary |
||
(3 intermediate revisions by the same user not shown) | |||
Line 9: | Line 9: | ||
== Description == | == Description == | ||
[[File:HC-SR04 Distance Measuring.jpg|thumb|HC-SR04 Distance Measuring Module]] | |||
[[File:Hc-sr04-schematic.jpg|thumb|HC-SR04 Distance Measuring Module Schematic]] | |||
* Working Voltage : 5V(DC) | * Working Voltage : 5V(DC) | ||
Line 47: | Line 50: | ||
normal work of the module. | normal work of the module. | ||
Line 62: | Line 65: | ||
! scope="row"| Stock | ! scope="row"| Stock | ||
| 10pcs | | 10pcs | ||
|} | |||
== Pinout == | |||
{| class="wikitable" | |||
! rowspan="5" | [[File:HC-SR04 Distance Measuring.jpg|center|100px|HC-SR04 Distance Measuring]] | |||
! Pin | |||
! Mapping | |||
|- | |||
| VCC | |||
| | |||
|- | |||
| Trig | |||
| | |||
|- | |||
| Echo | |||
| | |||
|- | |||
| GND | |||
| | |||
|- | |||
| colspan="3" | To edit table: [[File:HC-SR04.tgn]] | |||
|} | |} | ||
Latest revision as of 05:20, 25 April 2019
Features
HC-SR04 Distance Measuring Module |
|
https://bogza.ro/index.php/HC-SR04_Distance_Measuring_Module |
Description
- Working Voltage : 5V(DC)
- Static Current: Less than 2mA.
- Output Signal: Electric frequency signal, high level 5V, low level 0V.
- Sensor Angle: Not more than 15 degrees.
- Detection Distance: 2cm-450cm.
- High Precision: Up to 0.3cm
- Input Trigger Signal: 10us TTL impulse
- Echo Signal : output TTL PWL signal
Mode of connection
VCC trig(T) echo(R) GND
Use method
Supply module with 5V, the output will be 5V while obstacle in range, or 0V if not.The out pin of this module is used as a switching output when anti-theft module, and without the feet when ranging modules.
Note : the module should be inserted in the circuit before been power, which avoid producing high level of misoperation;if not, then power again.
Module Working Principle
- Adopt IO trigger through supplying at least 10us sequence of high level signal.
- The module automatically send eight 40khz square wave and automatically detect whether receive
the returning pulse signal.
- If there is signals returning, through outputting high level and the time of high level continuing is
the time of that from the ultrasonic transmitting to receiving. Test distance =(high level time * sound velocity (340M/S) / 2.
Note
This module is not suitable to connect with electric power, if you need to connect this module with electronic power,then let the GND terminal of this module to be connected first,otherwise, it will affect the normal work of the module.
Specifications
Parameter | Value |
---|---|
Module Size | 43mm(length)*21mm(width) |
Stock | 10pcs |
Pinout
Pin | Mapping | |
---|---|---|
VCC | ||
Trig | ||
Echo | ||
GND | ||
To edit table: File:HC-SR04.tgn |